This manual mainly introduces the usage instructions of the XSJ-DOR series relay modules. This series adopts bidirectional optocoupler isolation input, with normally open and normally closed relay outputs. The number of input/output channels ranges from 1 to 12 per board. The input terminals control the output terminals. When the input signal is triggered, the relay at the output will be activated. For more channels, please contact us for customization services.
1 Product Overview
1.1 Functions
◆ 1–12 channel digital input (high/low level detection);
◆ 1–12 channel digital output (relay control);
◆ Input signal type: PNP (high-level trigger) or NPN (low-level trigger);
◆ Supports dry contact (passive switch/mechanical switch) and wet contact (active sensor);
◆ Relay output rated current: 10A;
◆ Power and input indicator LEDs;
1.2 Features
◆ Taiwan YouTai bidirectional optocoupler;
◆ Brand-new original Omron relays;
◆ Key chips are all brand-new imported components;
◆ Industrial-grade product suitable for various applications;
1.3 Specifications
Specifications | |
| Power Supply | 3.3V / 5V / 12V / 24V DC |
| Power Consumption | Relay (Omron): 0.65W/channel, Digital input: 9mA/channel |
| Input Type | PNP/NPN, supports dry contact and wet contact |
| Input Channels | 1–12 channels |
| Input Method | Bidirectional optocoupler isolation |
| Output Specification | Relay brand: Omron, Rated load: 10A, 250V AC / 30V DC |
| Output Channels | 1–12 channels |
| Operating Temperature | -40°C to +85°C |
| Operating Humidity | 0%–95% (non-condensing) |
1.4 Wiring
| Wiring Table | |
| Label | Function |
| VCC | Power positive (3.3V/5V/12V/24V DC) |
| GND | Power ground |
| NO | Normally Open output |
| NC | Normally Closed output |
| COM | Common terminal |
| X | Signal input |
| S/S | Signal common |
1.5 Digital Input Wiring
.png)

1.6 Relay Output Wiring

2 Product Appearance